PACTware is the manufacturer and fieldbus-independent operating software for all field devices and protocols.
Pepperl Fuchs Driver Download For Windows 10 Pro
- The driver is for redundant I/O LB/FB by Pepperl & Fuchs. I have an old project developed by ex collegues, and now i nedd to do a modify. My system is Windows XP sp2 - S7 V5.5 - CFC V7.1 sp2 - SCL V5.3 I open the charts correctly but if i try to do a compilation a worning is emitted: 'A version for the driver library has to be selected'.
- For more than 35 years, Pepperl+Fuchs Comtrol has been a manufacturer & provider of quality networking and industrial data communication products. History & Development Pepperl+Fuchs Comtrol invented the first multi-port serial controller card for the PC. Directions US Headquarters: 100 Fifth Avenue NW New Brighton, MN 55112 Phone: +1 330 486 0001.
- Pactware hart software, free download. System Utilities downloads - PACTware by PACTware Consortium and many more programs are available for instant and free download.
PACTware brings together companies with a wide variety of skill sets. Designed as a manufacturer and fieldbus-independent solution, PACTware forms the framework for uniform device configuration and operation in the field of automation. PACTware handles the entire range of field devices via any communication channel.
The PACTware tool can be used to configure, operate, and diagnose all devices in a plant. PACTware uses a uniform operating and interface concept, which makes it the most widely available free FDT frame application for the user. PACTware is flexible even under the most varied operating conditions. Whether operated from a system engineering station or directly on-site: PACTware performs reliably from anywhere.
USB VIRTUAL COM PORT DRIVER Installation 2-12 5 2 Installation 2.1 Installation under Windows XP Installing the USB virtual COM port driver 1. If the handheld is still connected to the PC, disconnect it. Download the ZIP file containing the USB virtual COM port drive from www.pepperl-fuchs.com and extract the files to your PC.
The design of PACTware's user interfaces are based on clarity and intuitive operation. The view of the plant can be quickly and easily adapted to individual measuring tasks. Whether using presets or creating a special solution based on special parameters, PACTware supports the user at every step of the device configuration process.
PACTware supports all common communication protocols - regardless of the device type or task. PACTware integrates into all areas of the heterogeneous system landscape through manufacturer-independent interfaces and exchange formats that remain constant over time and a modular structure.
This is made possible by the globally established FDT (Field Device Technology) standard. FDT ensures uniform data exchange between devices and PACTware. DTMs ensure uniform operation of the devices.
Standardized software blocks, or 'Common Components', guarantee the best possible basic technology that is always up to date.
With its modular design, PACTware is open to future fieldbus standards and all current fieldbus standards. Additional functions that are available to all DTMs can be added flexibly via interfaces. These 'add-ins' allow for follow-up checks such as 'audit trails' or 'trending' across multiple devices.
The PACTware member companies make the DTMs that are suitable for their devices available for download via PACTware. This means that you only have one contact person for the device, the appropriate driver (DTM), and PACTware. Service and support are also provided from a single source.
Each PACTware installation can operate all HART devices. The setup includes a communication driver for common HART modems and a generic HART device DTM.
Datasheet excerpt: Technical data of HM-MT-USB-010031
Pepperl Fuchs Driver Download For Windows 10 Bit
Product Description | ||
---|---|---|
Interface for commissioning, calibrating, and acquiring data from HART field devices |
Supply | ||
---|---|---|
Input current | 30 mA at 5 V | |
Power supply | Powered by USB port , No external power required | |
Interface | ||
Interface type | USB port | |
Output | ||
Signal | 0.5 ± 0.1 Vpp trapezoidal wave at 1200/2200 Hz, 24 VDC at 40 mA to device | |
Galvanic isolation | ||
Output/interface | 1500 V DC | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
System requirements | ||
Operating system | Windows® 98 , 2000 , 32-bit XP , 32-bit Vista , 32- and 64-bit Windows® 7, and Windows® 10 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | 0 ... 95 % non-condensing | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | USB (type A) Connector , red and black test clips | |
Material | Polycarbonate | |
Dimensions | 75 mm x 33 mm x 15 mm | |
Cable length | 1.8 m 2-strand wire terminating in 2 test clips , 15.2 cm cable terminating in 1 USB type A connector | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |